Instead of buying 2 smaller panels one for each battery bank i was thinking about hooking up 2 charge controllers to the same solar panel.
Multiple solar panels to charge controller.
The connection of multiple solar panels in parallel arises from the need to reach certain current values at the output without changing the voltage.
Figure out how many solar panels you are going to need for your home first.
Large off grid solar and battery backup pv systems often require greater charging than a single controller can provide.
Connecting two solar panels to a single charge controller is is possible to connect 2 solar panels to a 30a charge controller.
The only time the voltages add together is when they are in series like in each row.
The solar panel disconnect switch is required because the batteries should be connected to the charge controllers before the solar panel is connected.
They are of different brands but will be mounted in the same direction.
You should think of a charge controller in this same sense.
Multiple charge controllers esp.
2 panels that produce 12 volts each in series produces a total of 24 volts.
So the worry is that if solar panels are running at the same time will they overcharge the battery because it now has two sources charging it.
On my boat i would add dc plugs for both batteries to connect the charge controllers.
Well assuming there is a charge controller fitted on the solar installation then both charge sources the battery charger and the solar system are regulated.
Mppt type connected to a single panel array can be an issue and should generally be avoided.
The meterhub was designed specifically for systems with multiple controllers.
In fact by wiring several solar panels in series we increase the voltage keeping the same current while wiring them in parallel we increase the current keeping the same voltage.
The solar panels are both 12 but one is 80w and the other is 120w.
I see that in xantrex manuals that you have to hook up separate arrays no mixup to each charge controller and hence consequently to the separate.
To meet high power charging requirements several solar controllers can be connected in parallel to a battery bank with each controller connected to its own separate pv subarray.
Multiple panels an array to a single controller is fine providing wiring is done right for the controller used.
In addition to displaying information from any individual controller or aggregated system totals it allows simultaneous initiation of an equalization charging cycle for all tristar or tristar mppt solar charge controllers in the system.
I ve a question regarding hooking up multiple units of the solar mppt charge controller if your load requirement is such that then you need multiple mppt charge controller for your pv system.